STM A213 Standard Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger Tubes
ASTM A213M-09 standard is issued under the fixed designation A 213/A 213M; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision.
This standard is issued under the fixed designation A 213/A 213M; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (′) indicates an editorial change since the last revision or reapproval.
Thisstandardhas been approved for use by agencies of the Department of Defense.
1.1 This specication2 covers seamless ferritic and austenitic steel boiler, superheater, and heat-exchanger tubes, designated Grades T5,TP304, etc. These steels are listed in Tables 1 and 2.
1.2 Grades containing the letter, H, in their designation, have requirements different from those of similar grades not containing the letter, H. These different requirements provide higher creep-rupture strength than normally achievable in similar grades without these different requirements.
1.3 The tubing sizes and thicknesses usually furnished to this specication are 18 in. [3.2 mm] in inside diameter to 5 in. [127 mm] in outside diameter and 0.015 to 0.500 in. [0.4 to 12.7 mm], inclusive, in minimum wall thickness or, if specied in the order, average wall thickness. Tubing having other diameters may be furnished, provided such tubes comply with all other requirements of this specication.
1 This specication is under the jurisdiction of ASTM Committee A01on Steel,Stainless Steeland Related Alloys and is the direct responsibility of Subcommittee A01.10 on Stainless and Alloy Steel Tubular Products.
Current edition approved April 1, 2009. Published April 2009. Originally approved in 1939. Last previous edition approved in 2009 as A 213/A 213M – 09.
2 For ASME Boiler and Pressure Vessel Code applications see related Specication SA-213 in Section II of that Code.
3 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. ForAnnualBookofASTM Standards volume information, refer to the standard’s Document Summary page on the ASTM website.
A 262 Practices for Detecting Susceptibility to Intergranu lar Attack in AusteniticStainless Steels
A 941 Terminology Relating to Steel,Stainless Steel, Re lated Alloys, and Ferroalloys
A 1016/A 1016M Specication for General Requirements for Ferritic AlloySteel, Austenitic Alloy Steel, and Stainless Steel Tubes
E112 Test Methods for Determining Average Grain Size
3. Terminology
4.1 It shall be the responsibility of the purchaser to specify all requirements that are necessary for products under this specication. Such requirements to be considered include, but are not limited to, the following:
4.1.1 Quantity (feet, metres, or number of lengths),
4.1.2 Name of material (seamless tubes),
4.1.3 Grade (Tables 1 and 2),
4.1.4 Condition (hot nished or cold nished),
4.1.5 Controlled structural characteristics (see 6.3),
4.1.6 Size (outside diameter and minimum wall thickness, unless average wall thickness is specied),
4.1.7 Length (specic or random),
4.1.8 Hydrostatic Test or Nondestructive Electric Test (see 10.1),
4.1.9 Specication designation and year of issue,
4.1.10 Increased sulfur (for machinability, see Note B, Table 1, and 15.3), and
5.1 Product furnished to this specication shall conform to the requirements of Specication A 1016/A 1016M, including any supplementary requirements that are indicated.
NPS, inch | Outside Diameter(mm) | Wall Thickness(mm) | Max. Length(M) |
1/8 | 10,3 | 1,24; 1,73; 2,40 | 12 |
1/4 | 13,7 | 1,65; 2,24; 3,02 | |
3/8 | 17,1 | 1,65; 2,31; 3,20 | |
1/2 | 21,3 | 1,65; 2,11; 2,77; 3,73 | |
3/4 | 26,7 | 1,65; 2,11; 2,87; 3,91 | |
1 | 33,4 | 1,65; 2,77; 3,38; 4,55 | 10 |
1 1/4 | 42,4 | 1,65; 2,77; 3,56; 4,85 | |
1 1/2 | 48,3 | 2,77; 3,68; 5,08 | |
2 | 60,3 | 3,91; 5,54 | 7 |
2 1/2 | 73,0 | 5,16; 7,01 |
Steel Grade | Tensile StrengthN/mm2(min) | Yield StrengthN/mm2(min) | Elongation % (min) |
TP304 | 515 | 205 | 35 |
TP304L | 485 | 170 | 35 |
TP316 | 515 | 205 | 35 |
TP316L | 485 | 170 | 35 |
TP321 | 515 | 205 | 35 |
T11 | ≥415 | ≥205 | 30 |
T12 | ≥415 | ≥220 | --- |
T13 | ≥415 | ≥205 | 30 |
Steel Grade | C | Si | Mn | Cr | Ni | Mo | S | P |
TP304 | 0,08 | 0,75 | 2 | 18 - 20 | 8 - 11 | - | 0,03 | 0,04 |
TP304L | 0,035 | 0,75 | 2 | 18 - 20 | 8 - 13 | - | 0,03 | 0,04 |
TP316 | 0,08 | 0,75 | 2 | 16 - 18 | 11 - 14 | 2 - 3 | 0,03 | 0,04 |
TP316L | 0,035 | 0,75 | 2 | 16 - 18 | 10 - 15 | 2 - 3 | 0,03 | 0,04 |
TP321 | 0,08 | 0,75 | 2 | 17 - 20 | 9 - 13 | - | 0,03 | 0,04 |
T11 | 0.05-0.15 | 0.50-1.00 | 0.30-0.60 | 0.5-1.0 | --- | 1.0-1.5 | ≤0.25 | ≤0.025 |
T12 | 0.05-0.15 | ≤0.50 | 0.30-0.61 | 0.80-1.25 | --- | 0.44-0.65 | ≤0.25 | ≤0.025 |
T13 | 0.05-0.15 | ≤0.50 | 0.30-0.60 | 1.90-2.60 | --- | 0.87-1.13 | ≤0.25 | ≤0.025 |
Tel:
E-mai:
Skype: