EVERBRIGHT

Technical Support
ASTM A53 Standard Specifications
ASTM A53 Standard Spec. for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless

ASTM A53 / A53M Standard covers seamless and welded black and hot-dipped galvanized steel pipe in NPS 1/8 to NPS 26.

The steel categorized in this standard must be open-hearth, basic-oxygen or electric-furnace processed and must have the following chemical requirements: carbon, manganese, phosphorus, sulfur, copper, nickel, chromium, molybdenum, and vanadium. The tubing shall undergo a seamless or welding process. Tension, bend, and flattening tests shall be performed to make sure that it must adhere to the mechanical properties of the standard. The hydrostatic test shall be applied, without leakage through the weld seam or the pipe body. Nondestructive electric test shall be made to make sure that the full volume of the pipe must be in accordance with the standard. The purchaser shall have the right to perform any of the inspections and tests set forth in this specification where deemed necessary to ensure that the pipe conforms to the specified requirements.

1.1 This specification covers seamless and welded black and hot-dipped galvanized steel pipe in NPS 1/8 to NPS 26 [DN 6 to DN 650] (Note 1), inclusive, with nominal wall thickness (Note 2) as given in Table X2.2 and Table X2.3. It shall be permissible to furnish pipe having other dimensions provided that such pipe complies with all other requirements of this specification. Supplementary requirements of an optional nature are provided and shall apply only when specified by the purchaser.
Note 1—The dimensionless designators NPS (nominal pipe size) [DN (diameter nominal)] have been substituted in this specification for such traditional terms as “nominal diameter,” “size,” and “nominal size.”
Note 2—The term nominal wall thickness has been assigned for the purpose of convenient designation, existing in name only, and is used to distinguish it from the actual wall thickness, which may vary over or under the nominal wall thickness.

1.2 This specification covers the following types and grades:
1.2.1 Type F—Furnace-butt-welded, continuous welded Grade A,
1.2.2 Type E—Electric-resistance-welded, Grades A and B, and
1.2.3 Type S—Seamless, Grades A and B.

Note 3—See Appendix X1 for definitions of types of pipe.
1.3 Pipe ordered under this specification is intended for mechanical and pressure applications and is also acceptable for ordinary uses in steam, water, gas, and air lines. It is suitable for welding, and suitable for forming operations involving coiling, bending, and flanging, subject to the following qualifications:
1.3.1 Type F is not intended for flanging.
1.3.2 If Type S or Type E is required for close coiling or cold bending, Grade A is the preferred grade; however, this is not intended to prohibit the cold bending of Grade B pipe.
1.3.3 Type E is furnished either no expanded or cold expanded at the option of the manufacturer.

1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.5 The following precautionary caveat pertains only to the test method portion, Sections 7, 8, 9, 13, 14, and 15 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
1.6 The text of this specification contains notes or footnotes, or both, that provide explanatory material. Such notes and footnotes, excluding those in tables and figures, do not contain any mandatory requirements.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

Scope

1.1 ASTM A53 / A53M Standard Specification covers seamless carbon steel pipe for high-temperature service (Note 1) in NPS 1/8 to NPS 48 [DN 6 to DN 1200] (Note 2) inclusive, with nominal (average) wall thickness as given in ASME B 36.10M. It shall be permissible to furnish pipe having other dimensions provided such pipe complies with all other requirements of this specification. Pipe ordered under this specification shall be suitable for bending, flanging, and similar forming operations, and for welding. When the steel is to be welded, it is presupposed that a welding procedure suitable to the grade of steel and intended use or service will be utilized.
NOTE 1: It is suggested, consideration be given to possible graphitization.
NOTE 2: The dimensionless designator NPS (nominal pipe size) [DN (diameter nominal)] has been substituted in this standard for such traditional terms as “nominal diameter,” “size,” and “nominal size.”
1.2 Supplementary requirements of an optional nature are provided for seamless pipe intended for use in applications where a superior grade of pipe is required. These supplementary requirements call for additional tests to be made and when desired shall be so stated in the order.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.4 The following precautionary caveat pertains only to the test method portion, Sections 11, 12, and 13 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Types and grades:
Type F—Furnace-butt-welded, continuous welded Grade A,
Type E—Electric-resistance-welded, Grades A and B, and
Type S—Seamless, Grades A and B.

This specification covers seamless carbon steel pipe for high-temperature service
Sizes (Seamless): 1/2″ NB – 60″ NB
Sizes (ERW): 1/2″ NB – 24″ NB
Sizes (SAW): 16″ NB – 100″ NB

Wall Thickness available:
Schedule 20 – Schedule XXS (heavier on request) up to 250 mm thickness.

Additional Testing:
NACE MR0175, NACE TM0177, NACE TM0284, HIC TEST, SSC TEST, H2 SERVICE, IBR, etc.

Chemical requirements
ElementType S
(seamless)
Type EType F
(electric-
resistance welded)
(furnace-
welded pipe)

Grade AGrade BGrade AGrade BGrade A
Carbon max. %0.250.300.250.300.3
Manganese %0.951.20.951.21.2
Phosphorous, max. %0.050.050.050.050.05
Sulfur, max. %0.0450.0450.0450.0450.045
Copper, max.%0.400.400.400.400.4
Nickel, max. %0.400.400.400.400.4
Chromium, max. %0.400.400.400.400.4
Molybdenum, max. %0.150.150.150.150.15
Vanadium, max. %0.080.080.080.080.08
Hot-dipped Galvanizing:

Sets standards for coating of pipe with zinc inside and outside by the hot-dipped process. Weight of coating must not average less than 1.8 oz. per square foot and not less than 1.6 oz. per square foot.

PERMISSIBLE VARIATIONS IN WALL THICKNESS

The minimum wall thickness at any point shall not be more than 12.5% under the nominal wall thickness specified.

PERMISSIBLE VARIATIONS IN WEIGHTS PER FOOT

Plus or minus 10%

PERMISSIBLE VARIATIONS IN OUTSIDE DIAMETER

Outside Diameter at any point shall not vary from standard specified more than:

For NPS 1 1/2 and Smaller SizesFor NPS 2 and Larger Sizes
1/64″
1/32″ under1% over1%under
TENSILE REQUIREMENTS

Seamless and Electric-resistance-weldedContinuous-Welded

Grade AGrade B
Tensile Strength, min., psi48,00060,00045,000
Yield Strength, min., psi30,00035,00025,000
NUMBER OF TESTS REQUIRED

Seamless and Electric-Resistance-Welded — Bending, flattening, tensile on one length of pipe from each lot of 500 lengths or less of a size. Continuous-Weld — Bending, flattening, tensile

NPS 1 1/2 & smallerNPS 2 & larger
one / 25 tonsone / 50 tons
HYDROSTATIC TESTING

Hydrostatic inspection test pressures for plain end and threaded and coupled pipe are specified. Hydrostatic pressure shall be maintained for not less than 5 seconds for all sizes of seamless and electric-resistance-weld pipe.

MECHANICAL TESTS SPECIFIED

Tensile Test — Transverse required on ERW for NPS 8 and large. Sending Test (Cold) — STD and XS-NPS 2 and under XXS-NPS 1 1/4 and under.


Degree of BendDiameter of Mandrel
For Normal A53 Uses9012 x nom dia. of pipe
For Close Coiling1808 x nom dia. of pipe

Flattening Test — NPS 2 and larger STD and XS. (Not required for XXS pipe.)

LENGTHS

Standard Weight

  • Single Random — 16′ – 22′. 5% may be jointers. If Plain Ends — 5% may be 12′ – 16′.

  • Double Random — Shortest Length 22′, minimum average for order 35′.

Extra Strong and Double Extra Strong

  • Single Random — 12′ -22′. 5% may be 6′ – 12′.

  • Double Random (XS and lighter) — Shortest Length 22′, minimum average for order 35′.

  • Lengths longer than single random with wall thicknesses heavier than XS subject to negotiation.

REQUIRED MARKINGS ON EACH LENGTH

(On Tags attached to each Bundle in case of Bundled Pipe)

GENERAL INFORMATION
  • Couplings — Applied handling tight. Couplings, 2″ and smaller straight tapped, other sizes taper tapped.

  • Thread Protection — Applied to pipe 4″ and larger.

  • End Finish (unless otherwise specified) –STD or XS, or wall thicknesses less than 0.500 in. (excluding XXS): Plain and beveled

  • All XXS and wall thicknesses over 0.500 in.: Plain end square cut.